Skip to content

Power supply placement and cable rules from the manuals

Checked November 20, 2026

The power supply is the box between the wall outlet and the cable. Where it sits is a safety rule. It's not a matter of taste.

What the power supply is

Wikipedia describes the power for an electric robot as a separate source, usually in the form of a set-down transformer.1

Think of it as the part that steps the household current down for the robot. The cable plugs into it, and the box plugs into the wall.

How far from the pool

Two manuals agree. Same minimum.

Pentair's Prowler 710 guide says the power supply must be placed a minimum distance of 10 feet away from the pool. It warns that failing to do so could create an electrical hazard.2

SmartPool's Robo-Kleen manual says the power supply must be at a minimum distance of 10 feet from the edge of the pool. It adds that the cleaner needs to be able to reach all the walls from where the box sits.3

Setting up the power supplyPick a dry, sheltered spotKeep it the manual's distance from the poolUse the outlet type the manual namesThen connect the cable
Placement comes before anything gets plugged in.

Your model may give a different distance. Read the manual for your own robot. Distances and outlet rules can also differ by country, and these two manuals are written for North American outlets.

Dry, sheltered and not at the edge

Pentair says to put the power supply in a dry, sheltered area. It's water resistant, not waterproof, so it shouldn't be left out in the rain or placed in puddles.2

SmartPool says not to let the power supply become submerged in the pool, and not to place it on the edge of the pool.3

Which outlet

Pentair says a ground fault current interrupter, called a GFCI, must be in place to protect your electric outlet. A GFCI is the outlet or plug that cuts power fast when it senses a fault. Pentair calls for a 115V, three prong grounded GFCI outlet.2

SmartPool also says to make sure the outlet is protected by a GFCI or an earth leakage circuit interrupter.3

Outlet voltages differ between the US, Canada, the UK and Australia. A manual written for one voltage won't suit another. Use the one for your robot and your country.

If the outlet is too far

This is where you shouldn't improvise.

Pentair says the power supply cord goes into a 115V, three prong grounded GFCI outlet.2

If no outlet is close enough, ask the maker or a licensed electrician. Don't improvise a way to reach one.

Where in the pool

Placement of the power supply also changes how the cable lies. Beatbot says that, ideally, you place it near the center of the longest side of the pool.4

The length page shows how that fits with the cable's reach: how long a cable you need.

Cited material

  1. Automated pool cleaner, Wikipedia
  2. Pentair 710 User Manual, page 10 (Setting up the power supply), Pentair
  3. Robo-Kleen Manual, SmartPool Inc.
  4. Robotic Pool Cleaner Cable Keeps Tangling: Causes and Fixes, Beatbot